Raytek GS150 thermal imaging systems enable automated quality control in glass bending, forming, annealing, and tempering processes.
The GS150LE variant is especially designed for Low-E (low emissivity) glass / one-side coated flat glass. It features automatic emissivity correction.
The systems are based on the Raytek MP150 infrared line scanner, which has a max. resolution of 1024 points per line, a max. 150 Hz scanning frequency, and an up to 90° wide field of view.
SYSTEM PROPERTIES
• Automated temperature monitoring
• Visualization on PC
• Ethernet TCP/IP interface integrated in the line scanning system
• PC-independent alarm output
• PC-independent analog outputs 3 x 4 – 20mA
BENEFITS
• Improve profitability and product quality
• Reduce set-up time
• Detect defects quickly
• Automate quality monitoring for ISO9000
• Reduce scrap
• Efficiently manage the heat balance in the oven
• Automatically adjust the emissivity value when changing glass types or coatings
Measured temperature range: 100 to 950°C (212 to 1742°F)System accuracy: ±0.5°C or ±3°C (6°F)Repeatability: ±1°C (2°F)Optical resolution: 170:1 (90% energy)Ambient temperature: 0 to 50°C (32 to 122°F), with water cooling up to 180°C (356°F)Field of view: 90°Points per line: Up to 1024 pixelsScan rate: Up to 150 HzPower supply: 24 VDC ± 25%, 1 AEthernet communication: TCP/IP (10/100 Mbit/s)