Free Service. No commitment.
Only for professionals

+ 240 000 products and services, 300 000 leads/year

Receive your catalog immediately

Your contact details :

By clicking above, I authorise Industry Plaza, of the company IPD (RCS Créteil France 490 727 633) and its partners, to send me quotes and information. IPD or any company in the Infopro Digital group may use your details to offer you, on their behalf or that of their clients, products and/or services useful for your professional activities or to include you in professional directories. To exercise your rights, to oppose this or to find out more: Privacy Policy.

Catalogue excerpt Temperature management

CT e k n i s ® TEMP-PLATE Irreversible Temperature Recording Labels F www.teknisfrance.com.com C Utilisation des étiquettes de contrôle de température Temp-Plate® dans les fabrications de semiconducteurs, silicium et les Fabrication de plaquettes et de circuits intégrés TeknisWahl a spécialement conçu des étiquettes Temp-Plate pour l'assurance de la qualité lors de la production de semi-conducteurs, de plaquettes de silicium et de circuits intégrés. La partie chauffage et polymérisation d'une ligne de production de semi-conducteurs est essentielle à la fabrication des composants de haute qualité demandés par les fabricants de produits électroniques à la pointe de la technologie. Les étiquettes Temp-Plate® sont appliquées sur le substrat de silicium pendant le processus de fabrication pour garantir que les températures de durcissement correctes sont respectées et que les matériaux ne sont pas affaiblis par une surchauffe au cours de cette étape de production. Nous avons beaucoup de clients qui utilisent des étiquettes Temp-Plate pour le système Etch, les FPD, les CVD, etc., qui s’appliquent sur les surfaces des Wafers. Le Wafer est transportée en plusieurs étapes dans l’équipement; il ne peut pas voir la température de chaque surface de la plaquette à l'aide d'appareils de mesure de température pendant l'opération. Temp-plate est autorisé à contrôler les conditions de réglage de l'équipement. Les étiquettes TeknisWahl Temp-Plate® série 450 sont spécialement conçues pour résister aux rigueurs de la production de semi-conducteurs. Les étiquettes sur base Kapton imprimées à l'envers sont conçues pour résister à l'exposition à une chaleur intense, aux ulta-videset aux gaz corrosifs. Les étiquettes Temp-Plate® série 450 mesurent 5 mm de haut et 16,5 mm)de large et sont fabriquées exclusivement aux États-Unis. www.teknis-france.com Tel : +33 1 39 23 84 00 p.guillaume@teknis-france.com Table of Contents and Introduction Temp-Plate® Irreversible Temperature Recording Labels Table of Contents Temp-Plate Introduction . . . . . . . . . . . . . . . 2, 3 Temp-Plate Applications . . . . . . . . . . . . . . . 4, 5 4 Position Temp-Plates. . . . . . . . . . . . . . . . . . 5 3, 6 & 8 Position Temp-Plates . . . . . . . . . . . . 6 Single Position Temp-Plates . . . . . . . . . . . . . . 7 NEW! Wahl Breakers . . . . . . . . . . . . . . . . . . . 7 IC Batch and Vacuum Chamber Temp-Plates . 8 Special Unmarked 4 Position Temp-Plate. . . . 8 Temp-Plate Specifications. . . . . . . . . . . . . . . . 9 Hot Hands Temperature Monitors. . . . . . . . . 10 Temp-Spy Low Cost Labels . . . . . . . . . . . . . 10 Reversible Temp-Plates, while supplies last . . . . 11 NEW! WB130 Wahl Breaker Overheat Indicators for Predictive Maintenance Monitors Circuit Breaker & Electrical Equipment Temperature for Overheat see page 7 for details • Continuously monitors electrical equipment. These economical non-reversible chemical change temperature labels instantly record an overheat occurrence and provide a permanent, NISTtraceable record. Temp-Plates are used in thousands of applications where other surface temperature monitoring and recording methods are impractical, cost prohibitive, or inaccurate. Wahl Temp Plate Temperature Recording Labels are: • Easy, self-adhesive installation on most surfaces • Heat-sensitive indicator “positions” turn permanently black when the rated temperature points are reached or exceeded • Positions are carefully graduated to allow readily visible temperature history information • Calibrated to ±1% NIST traceable accuracy from 90°F to 500°F (32°C to 260°C) • Wide selection of temperature ranges (both °F and °C), sizes, and number of recording positions Wahl Temp-Plate P/N 240-151F sample shown at actual size after exposure to progressively higher temperatures. Each temperature position turns irreversibly black at the rated temperature point. • Provides a permanent record of overheating • High-visibility graphics (red, white and black) ensure easy, quick, and positive readings, even in low-light conditions and small label sizes • Each temperature position is clearly printed with the rated temperature • Resistant, when properly installed, to solvents, fuels, grease, oil, water and steam • Continuous monitoring with no interruption due to power failure or battery exhaustion Easy to Use-Simply peel off backing of self adhesive Temp-Plates, and apply to any clean surface. Only .010" thick. WARRANTY Continued Innovation Since 1836 ISO 9001:2008 CERTIFIED 2 IMPORTANT NOTE: All labels 120°F/48°C and below are considered low temperature and are shipped with an ice pack to prevent the labels from turning in transit. They are shipped by Fed Ex Express Overnight. These labels should be refrigerated upon receipt or they could turn before their intended use.

Content here above is automatically converted from catalogue in pdf format. Look & feel is altered compared to the document you will receive.

YOUR REQUEST FOR Catalogue CONCERNS :

Temperature  management

Temperature management

TEKNIS France

  • Free and without commitment
  • Selected suppliers get in touch with you
  • Our customer service is at your disposal on +33 (0)1 77 92 99 79
    Monday to Friday, 9am-6pm
    or by email