Configure measurement tasks with ease via the display
High-resolution light grid: with beam separation of 5 mm, 10 mm, 20 mm, 25 mm, 30 mm und 50 mm
Available with three push-pull switching outputs or two analog outputs
Display configuration with selected, pre-programmed measuring functions
Monitoring height up to 3.2 m
Operating range up to 8.5 m
Optical synchronization of sender and receiver
Cloning function via IO-Link
Temperature range from –30 °C to +55 °C
Connection type: Male connector M12, 5-pin
Switching output: 2 x Analog, 1 x Q (push-pull)
Beam separation: 5 mm
Operating range: 5 m
Detection height: 295 mm
Communication interface: IO-Link
Data interface (hardware): 2 x analog + 1 x Q (IO-Link)