Length L of the gearmotor as a funtion of reduction and outlet number of revolution with the standard motor 763 60 output W 3400 Rpm loadness, 12/24 Vdc. Outlet shaft is supported by two coupled screened bearings.
The motor has an electrical suppressor system for the CE standard.
The motor and the reduction gear are both plated for corrosion strength.
Connecting 2 wire 0,75 x 250 mm.
* The speed rotation can change of ± 10%.
The S1 load test was made using a 4 A corrent in the air with an increase of temperature of 70° C.
The S2 load test was made using a 8.5 A corrent in the air with a timing 5` ON 5` OFF with an increase of temperature
of 80° C max. The starting corrent is 18 A and cannot be mantained for more than 2.
Max forces which may act on the outlet shaft: Axial 30 kg, Radial 40 kg on the extremity of outlet shaft.
It is possible to apply an encoder.