CATALOGUES
WHITE PAPERS
PRESS RELEASES
DH50
- Air flow (m3/h) : 50
- Process temperature NT (°C ) : -
- Process temperature MT (°C ) : 60-150
- Process temperature HT (°C ) : -
- Dew point (°C) : -50
- Static pressure (mbar) : -
- Blow. power proc. ( kW) : 0.135
- Blow. power regen ( kW) : 0.01
- Power heating proces NT ( kW) : -
- Power heating proces MT ( kW) : 2.5
- Power heating proces HT ( kW) : -
- Power heating regen. ( kW) : 1.5
- Installed power total NT ( kW) : -
- Installed power total MT ( kW) : 4.2
- Installed power total HT ( kW) : -
- Abs. med. pow. at 80° C ( kW) : 1.4
- Voltage (V/H) : 230/50
- Weight (kg): 40
DH80
- Air flow (m3/h) : 80
- Process temperature NT (°C ) : -
- Process temperature MT (°C ) : 60-150
- Process temperature HT (°C ) : -
- Dew point (°C) : -50
- Static pressure (mbar) : -
- Blow. power proc. ( kW) : 0.45
- Blow. power regen ( kW) : 0.01
- Power heating proces NT ( kW) : -
- Power heating proces MT ( kW) :2.5
- Power heating proces HT ( kW) : -
- Power heating regen. ( kW) : 1.5
- Installed power total NT ( kW) : -
- Installed power total MT ( kW) : 5.5
- Installed power total HT ( kW) : -
- Abs. med. pow. at 80° C ( kW) : 2.3
- Voltage (V/H) : 230/50
- Weight (kg): 42
DH160
- Air flow (m3/h) : 160
- Process temperature NT (°C ) : -
- Process temperature MT (°C ) : 60-150
- Process temperature HT (°C ) : -
- Dew point (°C) : -50
- Static pressure (mbar) : -
- Blow. power proc. ( kW) : 0.9
- Blow. power regen ( kW) : 0.135
- Power heating proces NT ( kW) : -
- Power heating proces MT ( kW) : 2.5
- Power heating proces HT ( kW) : -
- Power heating regen. ( kW) : 3.5
- Installed power total NT ( kW) : -
- Installed power total MT ( kW) : 11.5
- Installed power total HT ( kW) : -
- Abs. med. pow. at 80° C ( kW) : 4.9
- Voltage (V/H) : 230/50
- Weight (kg): 70
DH250
- Air flow (m3/h) : 250
- Process temperature NT (°C ) : -
- Process temperature MT (°C ) : 60-150
- Process temperature HT (°C ) : -
- Dew point (°C) : -50
- Static pressure (mbar) : -
- Blow. power proc. ( kW) : 1.1
- Blow. power regen ( kW) : 0.135
- Power heating proces NT ( kW) : -
- Power heating proces MT ( kW) : 2.5
- Power heating proces HT ( kW) : -
- Power heating regen. ( kW) : 5
- Installed power total NT ( kW) : -
- Installed power total MT ( kW) : 15.3
- Installed power total HT ( kW) : -
- Abs. med. pow. at 80° C ( kW) : 7.3
- Voltage (V/H) : 230/50
- Weight (kg): 80
INTERNET USERS ALSO CONSULTED ON THE CATEGORY DEHYDRATOR FOR PLASTIC
See also
Buyers
Find your suppliers Complete your request and let our teams find you the best deals available.Suppliers
Find your future clients List your products and services to enhance your web presence and receive qualified enquiries.